Permit: TC-COM-0925-01634

Parcel: 14118602A


Addresses:

10015 E OLD VAIL RD

Inspection Status: Re-inspection required

Inspection History: COT - HCPL - Rough Soil 

Date Description Inspector Results Comments
02/24/2026 COT - HCPL - Rough Soil  Re-inspection required 2-24-26: verified trench depth on a 1 1/2" domestic water line from northeast section of site that runs approximately 400' east. Do not backfill until we verify tracer wire is in place.
03/11/2026 COT - HCPL - Rough Soil  Partial Pass 3/11/26: plumbing underground approved at GL B-E/ 1-4. Ok to proceed with backfill.
05/14/2026 COT - HCPL - Rough Soil  Partial Pass 5-14-26: reinforcement at slab on grade for area's receiving, dairy cooler, freezer, produce cooler, stock area, produce /bulk prep cooler, meat deli cooler verified per detail's S300/Details-1, 10A, 5, 6, 8, keynote 4. Okay for concrete placement at progress areas.
05/21/2026 COT - HCPL - Rough Soil  Partial Pass 5/21/26 partial pass pre slab, east side meat cooler, south side front entrance
05/28/2026 COT - HCPL - Rough Soil  Partial Pass 5-28-26: Preslab inspection- Vapor barrier with 6" overlap, wire mesh , steel diamond spacing, reinforcement at isolation columns & wire mesh for slab on grade at sales floor approved. Okay for concrete placement at progress areas.
06/04/2026 COT - HCPL - Rough Soil  Partial Pass 6/4/26: plumbing intermediate for PVC (DWV) and Copper (Domestic) at produce prep Area located behind coolers and freezers approved. Hangers and supports above ceiling will be looked at during above ceiling inspection.