| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/25/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | Partial pass. Stem wall approved per third party report. 2/25/2026 | |
| 03/02/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 3/2/26: first lift at 4' CMU wall GL A/2.6-1, A-F/ 1 | |
| 03/04/2026 | COT - HCBU - Masonry Pregrout | Passed | ||
| 03/06/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 3-6-26: reinforcement at CMU wall from GL/ 1-4/ F-E at the north & F-C at the south exterior wall. Okay to grout 2nd lift at 8' 8". | |
| 03/09/2026 | COT - HCBU - Masonry Pregrout | Not Ready | 3-9-26: not ready-contractor will reschedule. | |
| 03/11/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 3/11/26: partial pass second lift at exterior CMU East walls, 3rd lift at WEST walls approved. | |
| 03/16/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | SouthWest wall 60’. 4th lift. Entire South wall 3rd lift. Entire East wall 3rd lift. Okay to grout all progress areas. 3/16/2026 |
|
| 03/19/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 3/19/26: 3rd lift approved at east and west walls, 2nd lift approved at north and south walls | |
| 03/25/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 3-25-26: reinforcement at west & south cmu walls approved. Okay to grout 5th lift. | |
| 04/01/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 4-1-26: okay to grout west cmu wall-6th lift. Submit 3rd party inspector's report for missed lift onto portal for review. | |
| 04/02/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 4-2-26: reinforcement for top out at south & east wall verified per plans. Top out at West cmu wall up to G/L-D & 5th lift at north wall from G/L-F to G/4-2.1 approved. Okay to grout progress areas. | |
| 04/03/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 4-3-26: okay to grout 6th lift from G/L 2.1-1/G-F. | |
| 04/06/2026 | COT - HCBU - Masonry Pregrout | Not Ready | 4-6-26: not ready-reschedule at your convenience. | |
| 04/07/2026 | COT - HCBU - Masonry Pregrout | Not Ready | 4-7-26: not ready. | |
| 04/08/2026 | COT - HCBU - Masonry Pregrout | Partial Pass | 4-8-26: reinforcement at north wall top out from G/L 4-1-G-F & west wall from G/L-1/G-D verified per plans-okay to grout progress areas.Reinforcement for on 4 cmu columns from G/L-A.3/1-2.6 verified per details- okay to grout at 3' from grade. |