Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - HCBU - Exterior Clips/Sheathing
Permit Number - TC-COM-0924-01779
Inspection Description - COT - HCBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/22/2025 | COT - HCBU - Exterior Clips/Sheathing | Re-inspection required | Nailing and anchor bolts at shear walls not per schedule. Add jack studs at main entry. Loose sheathing throughout. Add vertical fire blocking at every 10´west wall. Add cs16 straps at exterior corner walls. Stopped inspection. 4/22/2025 | |
| 04/29/2025 | COT - HCBU - Exterior Clips/Sheathing | Partial Pass | ||
| 05/06/2025 | COT - HCBU - Exterior Clips/Sheathing | Partial Pass |