Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - HCBU - Excavation/Rebar/Zoning
Permit Number - TC-COM-0923-02246
Inspection Description - COT - HCBU - Excavation/Rebar/Zoning
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 7-23-25: excavation/reinforcement for all footings verified per plans-Okay to pour. | |
| 09/22/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 9-22-25: slab on grade reinforcement verified per plans with #4's @ 18" o.c.-okay for concrete placement at progress areas. | |
| 10/01/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 10-1-25: reinforcement for eastern interior & exterior CMU wall verified per plans. Okay to grout 2nd lift at 8'. Also, embeds on exterior west wall approved. Okay to continue with construction at progress areas. | |
| 10/06/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 10-6-25: reinforcement verified per plans. Okay for grout west exterior wall at 4th lift-wall height at 14'. | |
| 10/16/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 10-16-25: reinforcement on all walls verified per plans-top out at north wall 18 8" & parallel walls and chase walls at 18' 8", East wall at 18' 8"& 16'4 ", south wall at 20', west wall at 19' 4", middle wall at 17'4", other middle wall at 18 and southwest wall at 19' 4". Okay to grout top out walls and remaining walls for 5th. lift. | |
| 10/21/2025 | COT - HCBU - Excavation/Rebar/Zoning | Passed | Passed 10/21/25 |