Parcel: 14036349A


Addresses:

5075 E VALENCIA RD


Inspection Status: Partial Pass

Inspection History: COT - HCPL - Sewer 

Permit Number - TC-COM-0923-02246

Inspection Description - COT - HCPL - Sewer 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
07/31/2025 COT - HCPL - Sewer  Partial Pass Partial pass. Approximately 120' in place. Okay to backfill progress areas. Shading material is required. Once completed pressure test is required. Verify tape is in place also. 7/31/2025
08/04/2025 COT - HCPL - Sewer  Partial Pass Partial pass. Approximately 120' in place. Okay to backfill progress areas. Shading material is required. Once completed pressure test is required. Verify tape is in place also. 7/31/2025
8/4/25: 30' in place. Ok to backfill progress areas. Shading material required.
08/06/2025 COT - HCPL - Sewer  Partial Pass Sewer line running north and south. With Wye branching off to catch grease interceptor. Approximately 25’. Three clean outs stubbed up. 8/6/2025
08/07/2025 COT - HCPL - Sewer  Not Ready
08/08/2025 COT - HCPL - Sewer  Partial Pass 8-8-25: verified 6" SDR35 PVC sewer line and tracer wire-Okay to backfill open trench of approximately 25'. Air test will be performed at a later date.
08/11/2025 COT - HCPL - Sewer  Passed 8-11-25: sewer pressure test at 4 psi approved. Okay to continue with construction.