Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - LCBU - Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2024 | COT - LCBU - Framing | Partial Pass | Partial pass. All ledgers, joist, beams, post, and wall studs per plan and matching details. (East end of buildings #2 and #3) (1st floor to 3rd floor) okay to proceed progress areas. 1/22/2024 | |
| 04/30/2024 | COT - LCBU - Framing | Canceled | ||
| 05/02/2024 | COT - LCBU - Framing | Re-inspection required | West end add blocking where plywood meet. Shear nailing not per schedule. Add missing anchor bolts. Nail off bottom plates every 16" o.c. Add straps from headers to columns. Buildings #2 and #3. 5/2/2024 | |
| 05/07/2024 | COT - LCBU - Framing | Partial Pass | 1/22/2024 West end add blocking where plywood meet. Shear nailing not per schedule. Add missing anchor bolts. Nail off bottom plates every 16" o.c. Add straps from headers to columns. Buildings #2 and #3. 5/2/2024 5/7/24: corrections made on west end of apartments for buildings #2 and #3. |
|
| 07/25/2024 | COT - LCBU - Framing | Re-inspection required | 1/22/2024 West end add blocking where plywood meet. Shear nailing not per schedule. Add missing anchor bolts. Nail off bottom plates every 16" o.c. Add straps from headers to columns. Buildings #2 and #3. 5/2/2024 5/7/24: corrections made on west end of apartments for buildings #2 and #3. 7/25/24: through the wall metal scuppers missing throughout on all sides of building (per plan). |
|
| 07/30/2024 | COT - LCBU - Framing | Re-inspection required | Inspection is called in for lath. Okay to proceed progress areas. 2/5/2024 1/22/2024 West end add blocking where plywood meet. Shear nailing not per schedule. Add missing anchor bolts. Nail off bottom plates every 16" o.c. Add straps from headers to columns. Buildings #2 and #3. 5/2/2024 5/7/24: corrections made on west end of apartments for buildings #2 and #3. 7/25/24: through the wall metal scuppers missing throughout on all sides of building (per plan). 7/30/24: corrections not made |
|
| 08/05/2024 | COT - LCBU - Framing | Passed |