Permit: TC-COM-0825-01553

Parcel: 12006316B


Addresses:

4225 S 6TH AV

Inspection Status: Partial Pass

Inspection History: COT - LCBU - Framing

Date Description Inspector Results Comments
04/03/2026 COT - LCBU - Framing Partial Pass 4-3-26: add shot pins within 6" at the ends of each plate and 32" o.c. thereafter. Add stud-shoes to the studs located at the southeast corner-non load bearing cannot be over notched more than 40%. Have architect of record submit a new floor plan showing the relocation of the ADA restrooms. Okay to continue with construction and will check for corrections at the intermediates.
04/29/2026 COT - LCBU - Framing Passed 4-29-26: framing approved.