Inspection History: COT - LCME - Mechanical Final 

Date Description Inspector Results Comments
05/26/2026 COT - LCME - Mechanical Final  Partial Pass 5-26-26: install evaporator coolers, install R3 insulation at hose bibs, label all disconnects-see NEC requirements for minimum lettering height requirements, seal HVAC line set at wall penetrations, HVAC refrigerant caps must be lockable, install hammer arrestor at dishwasher line, protection of HVAC line set requires shielding of not less than 6' from the equipment using removable material and adhesive tape is prohibited.
06/01/2026 COT - LCME - Mechanical Final  Passed 6-1-26: plumbing & mechanical final approved.