Inspection Status: Re-inspection required
Inspection History: COT - LCBU - Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 07/15/2025 |
COT - LCBU - Framing |
|
Re-inspection required |
7-15-25: extend osb to full height and add nails to marked locations, Simpson LUS26-missing nails, missing Simpson H-3 hardware at 2x4 stud to sill, add coil strap16 with 8 nails above and below interconnecting points at both post to beams. |
| 07/21/2025 |
COT - LCBU - Framing |
|
Passed |
7-21-25: framing approved. Okay to continue with construction. |