Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Re-inspection required
Inspection History: COT - HCBU - Exterior Clips/SheathingÂ
| Date |
Description |
Inspector |
Results |
Comments |
| 05/13/2026 |
COT - HCBU - Exterior Clips/Sheathing |
|
Re-inspection required |
5-13-26: have architect submit a metal framing RFI to the city for review. Install anchor bolts at warehouse shear wall @ 48" o.c., remove drywall at shear wall located at northeast corner to verify nailing at sheathing.Provide access to verify roof framing details. |
| 06/08/2026 |
COT - HCBU - Exterior Clips/Sheathing |
|
Re-inspection required |
6-8-26: missing A34 at warehouse to office entrance above door header,seal penetrations at marked areas, add shot pins with 1/2" disks at marked locations, missing nails at wood top plate splice, remove drywall at northeast shear wall to verify nailing at sheathing, missing bracing at 4' intervals and secure bent web of mtl. Stud brace to,to- track & to bottom flange of roof truss for walls parallel or perpendicular to truss, missing blocking mid height at wood framing, pending revision approval- city is requesting full set of metal framing plans/details. |