Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-COM-0725-01339

Parcel: 13734001D


Addresses:

1660 W VALENCIA RD

Inspection Status: Re-inspection required

Inspection History: COT - LCPL - Plumbing Final 

Date Description Inspector Results Comments
03/24/2026 COT - LCPL - Plumbing Final  Re-inspection required 3-24-26: install knee guards at restroom lavatories, adjust men's/girl's restroom doors to 5 pounds of pressure, install permanent labels at panels, seal all horizontal penetrations at firewall, label junction box near front office, remove exit sign above the northeast back classroom's door, install building address to where it's visible from parking lot.
03/27/2026 COT - LCPL - Plumbing Final  Passed 3-27-26: plumbing final approved.
12/19/2025 COT - LCPL - Plumbing Final  Not Ready 12-19-25: not ready.