| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/07/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | Footing is properly dug and cleaned out. Rebar reinforcement is in place per plan details along west side of property for retaining wall. Okay to pour concrete footings. 1/7/24: footing on south east and east of project site for retaining wall per plan. Ok to proceed |
|
| 03/14/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 3-14-25, reinforcement for Office-Building 1, details 105, 107, and 111 verified as per plans. Okay to pour concrete. | |
| 05/09/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | Building 2 warehouse. Partial pass hair pins have been cut and will be over lapped. Plans call for full length. Total of 21 pier footings. Okay for concrete placement at own risk. 5/9/2025 | |
| 05/14/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | Footing is properly dug and cleaned out. Rebar reinforcement is in place per plan details along west side of property for retaining wall. Okay to pour concrete footings. 1/7/24: footing on south east and east of project for retaining wall per plan. Ok to proceed 3-14-25, reinforcement for Office-Building 1, details 105, 107, and 111 verified as per plans. Okay to pour concrete. Building 2 warehouse. Partial pass hair pins have been cut and will be over lapped. Plans call for full length. Total of 21 pier footings. Okay for concrete placement at own risk. 5/9/2025 5/14/25: building 2 warehouse total (21) pier footings reinforced per plans, hair pins have been replaced with continuous full length. |
|
| 07/14/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 7-14-25: excavation/reinforcement on 9 warehouse footings/columns verified per plans. Okay | |
| 07/22/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 7-22-25: total of 6 canopy footers verified per Detail's 109 & 110. Okay to pour. | |
| 08/26/2025 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | 8-26-25: reinforcement on warehouse footings/foundations verified per details . Okay for concrete placement at progress areas | |
| 09/26/2025 | COT - HCBU - Excavation/Rebar/Zoning | Passed | 9-26-25: reinforcement for Building 1 cover slab on grade verified per plans-okay for concrete placement at progress areas. | |
| 11/25/2024 | COT - HCBU - Excavation/Rebar/Zoning | Partial Pass | Footing is properly dug and cleaned out. Rebar reinforcement is in place per plan details along west side of property for retaining wall. Okay to pour concrete footings. |