Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Partial Pass

Inspection History: COT - LCBU - Framing

Date Description Inspector Results Comments
09/04/2025 COT - LCBU - Framing Partial Pass 9-4-25: missing bracing per A6/Detail 5 at interior partitions. Contractor will possibly submit a RFI. Add drywall screws at base, joints, and edges 8" o.c. And 12" o.c. In the field. Same information applies plywood nailing. Reschedule inspection on drywall nailing prior to tape & texture. Okay to continue with construction at progress areas at own risk pending RFI approval.
09/15/2025 COT - LCBU - Framing Partial Pass 9-15-25: plumbing intermediates approved, frame out SA for HVAC at restrooms, submit architect letter as an attachment for framing RFI. Okay to continue at own risk pending RFI approval. Drywall nailing approved-okay to tape & texture at progress areas.
09/17/2025 COT - LCBU - Framing Passed 9-17-25: framing inspection approved.