Permit: TC-COM-0625-01114

Parcel: 13219101A


Addresses:

4697 S CAMPBELL AV

Inspection Status: Partial Pass

Inspection History: COT - HCPL - Plumbing Progress 

Date Description Inspector Results Comments
04/01/2026 COT - HCPL - Plumbing Progress  Partial Pass 4-1-26: in wall domestic and DWV verified under test.
04/03/2026 COT - HCPL - Plumbing Progress  Partial Pass 4-3-26: add 10 mil tape to copper line making contact with above ceiling duct at lounge, add Boca plates to marked locations-protection of plastic DWV requires a plate that extends 2" above & below top plates. Okay to insulate exterior walls and will check for corrections at next inspection.
07/02/2026 COT - HCPL - Plumbing Progress  Passed 7-2-26: approved.