Inspection History Details
Inspection Status: Requested
Inspection History: COT - HCBU - Firewall/Fire Barrier/Firestop
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| COT - HCBU - Firewall/Fire Barrier/Firestop | Requested | |||
| 05/01/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | Re-inspection required | 5.1.26: Hot water lines 3/4" and larger shall be properly insulated with minimum R3 insulation, properly support pex line and DWV throughout, dryer exhaust must be constructed of smooth material, kitchen hood shall be constructed of smooth materials, fire caulking required throughout at common walls, proper secure low voltage, back to back receptacles with inserts are required to have putty pad installed, provide Documentation on how large penetrations will be sealed, separate MC cable from copper lines, seal all penetrations (from low volt, mechanical, sprinkler, plumbing) | |
| 05/05/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | Partial Pass | 5/5/26: Drywall inspection for electrical rooms east wall (in rooms 276,376,476,576,676,776) | |
| 05/08/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | Partial Pass | 5/8/2026 MEP approved above ceilings 2nd floor units 262,259,260,258,256,254,255,252,253,250,251,257,213,215. Okay to proceed progress areas. | |
| 05/11/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | Partial Pass | 5/11/26: draft stop installed in wall at units 118,120,122,124,126 | |
| 05/12/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | Partial Pass | 5/12/26: draft stop installed in wall at units 130,132,134,136,138,140 | |
| 05/14/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | Partial Pass | 5/14/2026 112, 114, 116, 118, 120, 122, 124, 126,128, 130, 132, 134, 136, 138, 140. demising walls and corridor seam below metal framing at ceiling okay to proceed with fire tape. 2nd floor draft stop in units 232-212 approved. Okay to proceed progress areas. 258,256,259,257 5/8” in between both walls (divided) approved. |
|
| 05/15/2026 | COT - HCBU - Firewall/Fire Barrier/Firestop | Partial Pass | Inter & Above ceiling 3rd floor rooms 362,359,360,358,356,354,352,353,350,351,348,346 approved. Okay to proceed progress areas. 5/15/2026 |