Permit: TC-COM-0624-01172

Parcel: 11504505A


Addresses:

812 E SPEEDWAY BL

Inspection Status: Re-inspection required

Inspection History: COT - HCBU - Building Above Ceiling 

Date Description Inspector Results Comments
05/01/2026 COT - HCBU - Building Above Ceiling  Re-inspection required 5.1.26: Hot water lines 3/4" and larger shall be properly insulated with minimum R3 insulation, properly support pex line and DWV throughout, dryer exhaust must be constructed of smooth material, kitchen hood shall be constructed of smooth materials, fire caulking required throughout at common walls, proper secure low voltage, back to back receptacles with inserts are required to have putty pad installed, provide Documentation on how large penetrations will be sealed, separate MC cable from copper lines, seal all penetrations (from low volt, mechanical, sprinkler, plumbing)
05/05/2026 COT - HCBU - Building Above Ceiling  Partial Pass 5/5/26: M.E.P APPROVED ABOVE CEILING IN STUDIO UNITS 1ST FLOOR (112,114,116,118,120,122,124,126,128,130,132,134,136,138,140)
05/06/2026 COT - HCBU - Building Above Ceiling  Partial Pass 5/6/2026 MEP approved above ceilings 2nd floor units 212-240. Okay to proceed progress areas.
05/08/2026 COT - HCBU - Building Above Ceiling  Partial Pass 5/8/2026 MEP approved above ceilings 2nd floor units 262,259,260,258,256,254,255,252,253,250,251,257,213,215. Okay to proceed progress areas.
05/13/2026 COT - HCBU - Building Above Ceiling  Partial Pass 5/13/26:In-Wall and Above Inspection for Unit 112
05/15/2026 COT - HCBU - Building Above Ceiling  Partial Pass Inter & Above ceiling 3rd floor rooms 362,359,360,358,356,354,352,353,350,351,348,346 approved. Okay to proceed progress areas. 5/15/2026
05/18/2026 COT - HCBU - Building Above Ceiling  Partial Pass 5/18/26: shower wall fire taping rooms (134,136,138), shower walls 2nd floor screw inspection ( 212,214,216,218,220,222,224,226,228,230), MEP rooms 316,322,317,330,319, over notched studs require fix, code compliance nail plates required at plumbing walls
05/29/2026 COT - HCBU - Building Above Ceiling  Partial Pass 5/29/26:MEP approved In rooms 462,460,459,471,458,456,454, 452,450,453,455,457,413
06/01/2026 COT - HCBU - Building Above Ceiling  Partial Pass Partial pass 4th floor units 415,484,416,422,417,430,419,436,485,441,442 approved. Okay to proceed progress areas. 6/1/2026
06/03/2026 COT - HCBU - Building Above Ceiling  Partial Pass 6/3/26: above ceiling MEP and framing approved In rooms (184,179.4,179.3,179.2,180,180.183,183A,178.1,178.2,178.3,178.4,178.5,178.6,)
06/04/2026 COT - HCBU - Building Above Ceiling  Partial Pass 6/4/26: MEP approval in rooms 446,448,451,443

Fastener spacing approval at 2nd layer behind tubs in rooms 251,250,252,253,255,257,260,259,213,215,

Fire tape at areas behind tubs in rooms 254,256,258,262
06/08/2026 COT - HCBU - Building Above Ceiling  Partial Pass 6/8/26: 3rd floor corridor approved and draft stop between partition walls.