Inspection History: COT - HCEL - Electrical Above Ceiling 

Date Description Inspector Results Comments
04/08/2024 COT - HCEL - Electrical Above Ceiling  Re-inspection required Ducts must be strapped and properly supported throughout. Cannot rest on pex lines and other mechanical equipment., registers and lighting fixtures must be strapped and secured by seismic wire, fire caulk needed at wall penetrations at bathroom, loose duct above ceiling wall dividing bathroom and refrigerator.
04/09/2024 COT - HCEL - Electrical Above Ceiling  Canceled 4/9/24: canceled per contractor
04/10/2024 COT - HCEL - Electrical Above Ceiling  Passed