Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: TC-COM-0525-01025

Parcel: 13014023A


Addresses:

4220 E 22ND ST

Inspection Status: Partial Pass

Inspection History: COT - HCPL - Plumbing Above Ceiling

Date Description Inspector Results Comments
06/09/2026 COT - HCPL - Plumbing Above Ceiling Partial Pass 6-9-26: add supports to DWV above ceiling at woman's restroom at 4' intervals. Wrap hot water lines. We will verify at upcoming inspections.
06/22/2026 COT - HCPL - Plumbing Above Ceiling Partial Pass 6.22.26
Tech restrooms GTG.
08/18/2026 COT - HCPL - Plumbing Above Ceiling Canceled
08/31/2026 COT - HCPL - Plumbing Above Ceiling Re-inspection required 8-31-26: secure DWV vertically at customer men's restroom and add 10 mil tape to in wall copper line making contact with metal framing.
09/01/2026 COT - HCPL - Plumbing Above Ceiling Partial Pass Phase 1A.