Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - HCPL - Plumbing Above Ceiling
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/12/2026 | COT - HCPL - Plumbing Above Ceiling | Not Ready | ||
| 04/15/2026 | COT - HCPL - Plumbing Above Ceiling | Re-inspection required | 4/14/26: DWV AND PEX LINES SHALL BE UNDER TEST PRIOR TO CALLING IN INSPECTION | |
| 04/20/2026 | COT - HCPL - Plumbing Above Ceiling | Partial Pass | 4th floor 416,418,419 3rd floor 320,319,318,317,316 2nd floor 220, 219, 216, 217, 218 DWV partial pass. 4/20/2026 |
|
| 05/04/2026 | COT - HCPL - Plumbing Above Ceiling | Partial Pass | 5/4/2026 Mock unit 420 drop lids approved. Okay to proceed progress areas. | |
| 05/18/2026 | COT - HCPL - Plumbing Above Ceiling | Re-inspection required | 5/18/26: 2nd and 3rd floor corridors in walls at north building approved. In-wall MEP of 1st floor rooms (101,102,103,104,105,106,107,108,109,110,111,113,114) re-inspection required. Nail plates improperly installed must have (8) 3 -1/2" nails on both sides of 5x18 nail/strap, 5-sided gypsum box required at refrigerator water supply box, seal all penetrations at exterior and interior Fire walls, studs over notched at corridor require fix,properly secure electrical box at bathroom in room 106, room 103 (incomplete framing,plumbing, electrical, mechanical), room 106 (support condensate drain at bathroom) 107 ( leak at bathroom pex), 109 (exterior double studs over notched) 113 (stud at laundry room broken) partial pass for 108 kitchen wall | |
| 05/21/2026 | COT - HCPL - Plumbing Above Ceiling | Partial Pass | 5/21/2025 Partial pass. 101,102,103,104,105,106,107,108,109 110,111,112,113,114,117,118,119,120. Approved. All corrections were made. |
|
| 06/03/2026 | COT - HCPL - Plumbing Above Ceiling | Re-inspection required | MEP above ceilings 4th floor soffit areas in rooms 419(provide blocking on 3sides to registers. Add strap for dryer duct in closet, missing fire caulking at sprinkler line, add saddle straps to flex lines),418(open hole at light in closet, block registers in three sides seal off exterior fire walls),417(seal off feeder penetration,flex in closet smashed,tape off any tears in flex,add strap to 6” duct living area) stopped inspection. 6/3/2026 | |
| 06/08/2026 | COT - HCPL - Plumbing Above Ceiling | Not Ready | 6/8/2026 not ready per previous notes. Stopped inspections | |
| 06/10/2026 | COT - HCPL - Plumbing Above Ceiling | Partial Pass | 6/10/2026 partial pass. 4th floor MEP corrections were made and approved at dropped ceilings. Okay to proceed progress areas. | |
| 06/22/2026 | COT - HCPL - Plumbing Above Ceiling | Partial Pass | ||
| 06/25/2026 | COT - HCPL - Plumbing Above Ceiling | Partial Pass | 6.25.26 3rd Floor Soffit in rooms |
|
| 06/29/2026 | COT - HCPL - Plumbing Above Ceiling | Partial Pass | 6/29/2026 partial pass Rm 314 above ceiling pending fire tape at seams in bathroom and closet. | |
| 07/06/2026 | COT - HCPL - Plumbing Above Ceiling | Not Ready | Not ready. 211, 213, (exhaust fan net secured nor wired,214, provide blocking on three sides all registers, secure dryer duct. 215, remove fire tape and provide a new patch of drywall. 216, provide patch in bathroom . 217, provide patch in bathroom. 218, provide patch in bathroom,219 provide blocking at registers. Missing exhaust fan. 220 patch sprinkler hole 2nd in add straps to ducts in living area. 314 approved. 7/6/2026 | |
| 07/08/2026 | COT - HCPL - Plumbing Above Ceiling | Not Ready | ||
| 07/15/2026 | COT - HCPL - Plumbing Above Ceiling | Partial Pass | 2nd floor units above ceiling units 202,204,205,207,209,210(exhaust fan not tied in. 211,212,213(tape patch in bathroom, 214,215,216,217(shear wall damaged. 218,219,220,208,203,201,206. |