Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.
Inspection Status: Partial Pass
Inspection History: COT - HCBU - Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 09/15/2025 |
COT - HCBU - Framing |
|
Partial Pass |
9-15-25: mezzanine inspection-add shot pins to track at 12" o.c. Or 1/2" anchor bolts 4' o.c.. Also, provide a lift to verify screws at blocking & required clips at ledger per S3.0 Details 202. |
| 09/17/2025 |
COT - HCBU - Framing |
|
Partial Pass |
9-17-25: Partial pass on mezzanine framing. Shot pins & hangers verified per plans-construction is continuous and will verify H25's & A34's once remaining I-joists are in place. |
| 09/29/2025 |
COT - HCBU - Framing |
|
Partial Pass |
9-29-25: framing at mezzanine verified per plan-kickers at 4' o.c. to be verified at plywood is installed. Okay to drywall progress areas. |
| 10/06/2025 |
COT - HCBU - Framing |
|
Partial Pass |
10-6-25: framing at mezzanine approved. For any drywall -schedule a nailing inspection prior to tape & texture. |
| 12/04/2025 |
COT - HCBU - Framing |
|
Passed |
12-4-25: framing at mezzanine approved. |