Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - LCBU - Building Final
Permit Number - TC-COM-0523-01410
Inspection Description - COT - LCBU - Building Final
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2024 | COT - LCBU - Building Final | Re-inspection required | 9/25/24: anchor bolt spacing shall not exceed 6' o.c, anchor bolts required 12" from edge of sill plate, properly fasten loose anchor bolts, king/trimmer studs not per schedule, header not fastened with proper fasteners. | |
| 09/30/2024 | COT - LCBU - Building Final | Passed | Corrections were made. 9/30/2024 |