Permit: TC-COM-0426-00491

Parcel: 126134680


Addresses:

4515 E 22ND ST

Inspection Status: Partial Pass

Inspection History: COT - LCBU - Framing

Date Description Inspector Results Comments
07/20/2026 COT - LCBU - Framing Partial Pass 7/20/26: metal framing approved at Office 1 and office 2, metal framing approved at restroom 1 and restroom 2. (Per IBC 1210.2.1 In other than dwelling units, toilet, bathing and shower room floor finish materials shall have a smooth, hard, nonabsorbent surface. The intersections of such floors with walls shall have a smooth, hard, nonabsorbent vertical base that extends upward onto the walls not less than 4 inches (102 mm). Per IBC 1210.2.2 Walls and partitions within 2 feet (610 mm) of service sinks, urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of not less than 4 feet (1219 mm) above the floor, and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture.

Exception: This section does not apply to the following buildings and spaces:

1.Dwelling units and sleeping units.
2.Toilet rooms that are not for use by the general public and that have not more than one water closet.
Accessories such as grab bars, towel bars, paper dispensers and soap dishes, provided on or within walls, shall be installed and sealed to protect structural elements from moisture.)
07/20/2026 COT - LCBU - Framing Passed 7/20/26: metal framing approved at Office 1 and office 2, metal framing approved at restroom 1 and restroom 2.