Inspection Status: Partial Pass
Inspection History: COT - HCBU - Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 01/22/2026 |
COT - HCBU - Framing |
|
Partial Pass |
1-22-26: okay to tape & texture warehouse side office demising walls. |
| 01/29/2026 |
COT - HCBU - Framing |
|
Passed |
1-29-26: interior office framing approved. |
| 10/24/2025 |
COT - HCBU - Framing |
|
Partial Pass |
Partial pass, pending interior walls on the east side of building. |
| 11/17/2025 |
COT - HCBU - Framing |
|
Re-inspection required |
11-17-25: add screws per plans at upper deck to track and add shot pins at 12" o.c. at bottom track. |
| 11/18/2025 |
COT - HCBU - Framing |
|
Partial Pass |
11-18-25: metal framing on suite's demising wall approved-okay to drywall warehouse side. |