Inspection Status: Partial Pass

Inspection History: COT - HCBU - Exterior Clips/Sheathing 

Permit Number - TC-COM-0325-00519

Inspection Description - COT - HCBU - Exterior Clips/Sheathing 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
08/25/2025 COT - HCBU - Exterior Clips/Sheathing  Partial Pass 8-25-25: verified metal soffit framing along east, south and north side of site. Framing on furr out on new "bun wall" located on exterior east wall is missing anchor bolts/washers. Add an anchor bolt with washer within 12" of end of sill plate and anchor bolts/washers 48" o.c.-okay to install plywood but leave bottom section exposed to verify required corrections. Parapet reinforcing on rooftop was also inspected, an RFI was submitted to the city but has not been reviewed and approved. Okay to continue construction on rooftop at own risk-pending city approval.
09/02/2025 COT - HCBU - Exterior Clips/Sheathing  Partial Pass 9-2-25: exterior furr out on east side of building & nailing verified per plans-okay to continue with construction. Parapet framing/sheathing approved-okay to continue at progress areas at own risk pending RFI approval.
09/03/2025 COT - HCBU - Exterior Clips/Sheathing  Partial Pass 9-3-25: nailing on exterior sheathing for north wall of new addition verified per shear wall 1 schedule-okay to install exterior wall framing at new addition location. A-34's along eastern wall verified in place per detail 206. Schedule nailing/framing inspection when ready.
09/05/2025 COT - HCBU - Exterior Clips/Sheathing  Partial Pass 9-5-25: exterior clips/sheathing nailing approved at new addition. Hold-downs and anchor bolts verified per plans. Okay to lath exterior walls at progress areas.
09/30/2025 COT - HCBU - Exterior Clips/Sheathing  Partial Pass 9-30-25: in wall drywall nailing at dining area approved-okay for tape & texture at progress areas. Also, verified that all penetrations at storage room were fire foamed -okay to insulate & drywall.
10/27/2025 COT - HCBU - Exterior Clips/Sheathing  Partial Pass 10-27-25: lath inspection approved.
11/18/2025 COT - HCBU - Exterior Clips/Sheathing  Not Ready 11-18-25: plans for drive-thru menu boards must be submitted and approved by the city. To proceed with concrete placement at own risk, a letter from the architect or engineer of record would be required by the city. The document would have to be approved by the city before proceeding with the pour.