Permit: TC-COM-0225-00403

Parcel: 14020001B


Addresses:

860 E IRVINGTON RD

Inspection Status: Partial Pass

Inspection History: COT - HCBU - Building Progress

Date Description Inspector Results Comments
05/01/2026 COT - HCBU - Building Progress Partial Pass 5-1-26: reinforcement for cmu Stair 2 approved- okay to grout 5th lift at 20'. Reinforcement for cmu walls at Stair 3 top out approved for 13th lift at 52'
05/07/2026 COT - HCBU - Building Progress Partial Pass 5-7-26: Stair 2 cmu wall reinforcement approved. Okay to grout 8th lift at 32'.
Note: please submit 7th lift 3rd party report to the city portal.
08/27/2026 COT - HCBU - Building Progress Partial Pass 8-27-26: 1st floor above ceiling drywall screw inspection at south wing corridor approved.
09/03/2026 COT - HCBU - Building Progress Partial Pass 9-3-26: 2nd floor above ceiling drywall screw inspection at corridor approved for tape & texture.
09/10/2026 COT - HCBU - Building Progress Partial Pass 9/10/26: 3rd floor south wing above ceiling drywall screw inspection was previously inspected & approved on 9/9/26- see "framing" notes. Okay to tape & texture progress areas.
09/11/2026 COT - HCBU - Building Progress Partial Pass 9/11/26: 121-remove pex lines from wall, 125, 122- load bearing non-shear walls at anchor bolts with washers at 48" o.c...An anchor bolt is required within 12" from end of plates at intended wall fur out, 116, 115. Okay to fur out walls at room's 115, 116, 125.
10/05/2026 COT - HCBU - Building Progress Re-inspection required 10/5/26: Anchors must be spaced per approved plans, anchors required 12" from edge of ledger, anchors that are obstructing proper installation of hangers at joist must be corrected, framing not ready at south wing stairs #3
10/08/2026 COT - HCBU - Building Progress Re-inspection required
10/09/2026 COT - HCBU - Building Progress Partial Pass partial for 115-129 meps
10/13/2026 COT - HCBU - Building Progress Re-inspection required 10/13/26: add nails to LUS hangers and A34 at 2nd floor of Stair 3, add anchor bolts within 12" at the ends of ledger to masonry, correct anchor bolts that are both flush and those which are installed in an angle, add an A35 between 2nd /3rd floor at landing. Exterior strap north end 2nd floor verified per GA, 1st floor south wing units-fireblocking locking required at dropped ceiling areas. Noted: it appears that new penetrations were made at several pre-walked units-please make sure all penetrations are sealed. When ready schedule RC channel inspections and remove insulation from exterior walls at non inspected units along 1st floor south wing. We will advise when insulation may be installed.
Noted: Please schedule all future inspections according to type of inspection.
10/14/2026 COT - HCBU - Building Progress Re-inspection required 10/14/26: R/C Channel at Units 129 -122- add screws/backing to marked areas. Complete in wall RC Channels & install 2" AFF. Remove all AWG Wires/low voltage from above ceiling RC Channels & Reschedule inspection when ready.
10/15/2026 COT - HCBU - Building Progress Re-inspection required 10/15/26: 115-RC Channel not on 12" o.c., add shot pins to marked locations, and anchor bolt to marked area, remove all electrical wires/mechanical from RC channels above ceiling, interior load bearing party walls-add anchor bolts at 48" o.c.,117-shot pins to marked locations, anchor bolts to marked area, RC Channel screws at marked areas, insulate hot copper line at marked location, 120-missing RC Blocking and screws at marked locations, anchor bolts to marked locations, RC channel screws, note not all areas marked, add blocking and screws to RC, add RC screws at 12" o.c., add support to exhaust at marked locations, insulate hot copper line. 121-RC Connelly screws at marked locations, insulate hot copper line, add screws to drywall at end of walls, 118-RC at marked locations. 119-RC channels, insulate hot copper lines.
Note: unit's 122-129-insulate hot copper line and verify anchor bolts at interior load bearing party walls.