| 01/16/2026 |
COT - HCBU - Excavation/Rebar/Zoning |
|
Partial Pass |
1-16-26: excavation & reinforcement for elevator pit footing together with elevator sump pit section verified per S4.11 details 117 & 119-okay for concrete placement at progress areas. |
| 01/22/2026 |
COT - HCBU - Excavation/Rebar/Zoning |
|
Partial Pass |
1-22-26: reinforcement at 8" elevator walls verified per S4.11 Details 117 &111. Okay for concrete placement. |
| 03/03/2026 |
COT - HCBU - Excavation/Rebar/Zoning |
|
Partial Pass |
3/3/26: Preslab approved at pour 1 south west end of building |
| 03/16/2026 |
COT - HCBU - Excavation/Rebar/Zoning |
|
Partial Pass |
3/16/26: reinforcement and pt per approved plans at pour 4 |
| 03/18/2026 |
COT - HCBU - Excavation/Rebar/Zoning |
|
Partial Pass |
3/18/26: South Wing Pourback Rebar |
| 06/12/2026 |
COT - HCBU - Excavation/Rebar/Zoning |
|
Canceled |
6-12-26: please schedule this inspection for dumpster footings under your development package plan(site). |
| 07/27/2026 |
COT - HCBU - Excavation/Rebar/Zoning |
|
Partial Pass |
7-27-26: inspected a total of 14 light pole cages. 6 located on west side, 4 on the north and remainder at the east. Reinforcement all verified per plans, however, excavation/loose fill and debris were noted on the 3 light pole cage on west side. Please excavate to 7' 6" and provide 3" clearance at the bottom/remove loose fill. 2-located on the northwest side must have loose fill removed from bottom and provide 7' 6" on the light pole cage furthest northwest. The other cage on the north side must have the loose fill removed together with the 2- on the east side. Please schedule an inspection on those mentioned above prior to pour. Remainder are okay for concrete. |
| 07/29/2026 |
COT - HCBU - Excavation/Rebar/Zoning |
|
Partial Pass |