Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - HCBU - Masonry Pregrout
Permit Number - TC-COM-0223-00705
Inspection Description - COT - HCBU - Masonry Pregrout
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/14/2024 | COT - HCBU - Masonry Pregrout | Partial Pass | Detail 34 page S1.3 #5 22” overlap for elevator pit 1st lift detail 107 and 109. Okay to grout. 2/14/2024 | |
| 03/04/2024 | COT - HCBU - Masonry Pregrout | Partial Pass | Detail 34 page S1.3 #5 22” overlap for elevator pit 1st lift detail 107 and 109. Okay to grout. 2/14/2024 3/4/24: elevator pit reinforcement per plan second lift @5'4" above grade okay to grout. |
|
| 03/07/2024 | COT - HCBU - Masonry Pregrout | Partial Pass | 5’4 - 10’8 second lift at elevator pit. Total of 5 embedded plates. Detail #213 page S3.1. Continuous bond beam. Rebar per plan. Okay to grout. 3/7/2024 | |
| 03/12/2024 | COT - HCBU - Masonry Pregrout | Partial Pass | Detail 34 page S1.3 #5 22” overlap for elevator pit 1st lift detail 107 and 109. Okay to grout. 2/14/2024 3/4/24: elevator pit reinforcement per plan second lift @5'4" above grade okay to grout. 5’4 - 10’ second lift at elevator pit. Total of 5 embedded plates. Detail #213 page S3.1. Continuous bond beam. Rebar per plan. Okay to grout. 3/7/2024 3/12/24: 10'-15'4" third lift at elevator pit. 9 embedded plates. Reinforcement per plan ok to proceed. |
|
| 03/14/2024 | COT - HCBU - Masonry Pregrout | Partial Pass | 3/14/24: 4th lift okay to grout and continue to 5th lift | |
| 03/18/2024 | COT - HCBU - Masonry Pregrout | Partial Pass | 3/18/24: Final lift for elevator good to grout. | |
| 04/17/2024 | COT - HCBU - Masonry Pregrout | Partial Pass | ||
| 10/18/2024 | COT - HCBU - Masonry Pregrout | Passed |