Parcel: 14042074A


Addresses:

7150 S TUCSON BL


Inspection Status: Partial Pass

Inspection History: COT - HCME - Mechanical Progress 

Permit Number - TC-COM-0124-00185

Inspection Description - COT - HCME - Mechanical Progress 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
10/30/2024 COT - HCME - Mechanical Progress  Partial Pass 10/30/24: framing per plans at rooms 100,101,102,103,104,105,106,107,108,109,110,112,113,114,115,116,117,118,119,120,121,122,123,124,125,126,127,128,129. Ok to one side. Electrical in wall not complete missing grounding at multiple boxes and pending boxes being installed with conduit runs throughout, plumbing in wall at require plastic garments throughout, plumbing must be under test, access panels must be installed at shut off valves and A.V.V, pending completion of plumbing in walls and test.
12/19/2024 COT - HCME - Mechanical Progress  Partial Pass 10/30/24: framing per plans at rooms 100,101,102,103,104,105,106,107,108,109,110,112,113,114,115,116,117,118,119,120,121,122,123,124,125,126,127,128,129. Ok to one side. Electrical in wall not complete missing grounding at multiple boxes and pending boxes being installed with conduit runs throughout, plumbing in wall at require plastic garments throughout, plumbing must be under test, access panels must be installed at shut off valves and A.V.V, pending completion of plumbing in walls and test.
12/5/24: partial pass for plumbing in wall. Multiple hangers at copper piping must be replaced or protection must be added to prevent contact between copper piping and dissimilar metals.
12/19/24: electrical in wall passed. Ok to cover up walls.
12/19/24: hard duct installed and sealed throughout.