Permit: T99CM04856

Parcel: 11614163A

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T99CM04856

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/10/2000 FRAMING Approved
06/23/2000 FRAMING Not ready for Inspection IVRS - Inspection 0000*
04/17/2000 FRAMING Correction Required ADDTL COMMS - NEED TRUSS SUBMITTALS APPROVED
04/17/2000 FRAMING Partial Approval IVRS - Inspection 0000$
03/22/2000 FRAMING Correction Required ADDTL COMMS - DENIED - 1. NEED APPROVED TRUSS DRAWINGS AND STRAP RAFTER. 2. NEED LIGHT GAGE METAL STUDS COMPLETED.
03/22/2000 FRAMING Denied IVRS - Inspection 0000$
03/13/2000 FRAMING Correction Required ADDTL COMMS - DENIED - NOT READY. 1. INSTALL TICO NAILS IN ALL HOLES IN ALL TRUSS HANGERS. 2. INSTALL BOLTS IN HOLES OF GLU-LAM HANGERS. 3. NEED APPROVED TRUSS SUBMITTALS ON JOB SITE. 4. REPLACE BOLT NAILS IN TRUSS HANGERS. 5. INSTALL NUTS AND WASHERS IN ALL LEDGER BOLTS. 6. INSTALL STRAPS TO TOP CHORD AT SOUTH CENTER. 7. NEED A.B.S TO WITHIN 12 OF END. 8. NEED REPAIR TO P.A. AT NORTHEAST CORNER.
03/13/2000 FRAMING Denied IVRS - Inspection 0000$