Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T99CM04856
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/10/2000 | FRAMING | Approved | ||
06/23/2000 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
04/17/2000 | FRAMING | Correction Required | ADDTL COMMS - NEED TRUSS SUBMITTALS APPROVED | |
04/17/2000 | FRAMING | Partial Approval | IVRS - Inspection 0000$ | |
03/22/2000 | FRAMING | Correction Required | ADDTL COMMS - DENIED - 1. NEED APPROVED TRUSS DRAWINGS AND STRAP RAFTER. 2. NEED LIGHT GAGE METAL STUDS COMPLETED. | |
03/22/2000 | FRAMING | Denied | IVRS - Inspection 0000$ | |
03/13/2000 | FRAMING | Correction Required | ADDTL COMMS - DENIED - NOT READY. 1. INSTALL TICO NAILS IN ALL HOLES IN ALL TRUSS HANGERS. 2. INSTALL BOLTS IN HOLES OF GLU-LAM HANGERS. 3. NEED APPROVED TRUSS SUBMITTALS ON JOB SITE. 4. REPLACE BOLT NAILS IN TRUSS HANGERS. 5. INSTALL NUTS AND WASHERS IN ALL LEDGER BOLTS. 6. INSTALL STRAPS TO TOP CHORD AT SOUTH CENTER. 7. NEED A.B.S TO WITHIN 12 OF END. 8. NEED REPAIR TO P.A. AT NORTHEAST CORNER. | |
03/13/2000 | FRAMING | Denied | IVRS - Inspection 0000$ |