Inspection History Details
Inspection Status: Correction Required
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T99CM00305
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/09/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - NAIL O.S.B. AT NORTH ARCHED GABLE. | |
08/31/1999 | EXT METAL CLIPS/EXT SHEATHING | Correction Required | ADDTL COMMS - 1. PROVIDE HANGERS AT PLUMBING ON EAST SIDE UNDER CUT STUDS. 2. STRAP THE SOUTH END OF BALCONY FLOOR BEAM AT EAST SIDE. 3. NAIL THE STRAPS AT THE ROOF BEAM AT EAST SIDE. 4. RED HEAD THE PLATES AT ANY MAS STRAPS THAT DONT HAVE 6 NAILS. | |
08/31/1999 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* |