Inspection History Details
Inspection Status: Correction Required
Inspection History: FRAMING
Permit Number - T99CM00299
Inspection Description - FRAMING
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/15/1999 | FRAMING | Correction Required | ADDTL COMMS - APPROVED AS NOTED 1. SECURE PLATE (BOTTOM PLATES) WITHIN 12 OF EACH END. 2. CHECK TJIS FOR TORN OSB AT KNOCK OUTS (1ST FL. N.E.) 3. COMPLETE DROPS AND FIRE BLOCK. | |
07/07/1999 | FRAMING | Correction Required | ADDTL COMMS - 1. BLOCK HEADER/TOP PLATE AT 16 CC. 2. COMPLETE INTERMEDIATE TRADES. 3. BOLTS PLATES WITHIN 12 OF ENDS. 4. COMPLETE HDWE AND NAILING. | |
07/07/1999 | FRAMING | Partial Approval | IVRS - Inspection 0000* |