Permit: T98CM03008

Parcel: 11301084B


Addresses:

1341 E KING RD

Inspection Status: Correction Required

Inspection History: FRAMING

Date Description Inspector Results Comments
12/31/1998 FRAMING Correction Required ADDTL COMMS - 1. WILL NEED SOME TYPE OF SADDLE, OR STRAP FOR GLU-LAM BEAM ON C.M.U WALL. 2. OKAY TO COVER CONDUIT FROM SERV TO GARAGE. 3. SUB-PANEL IN GARAGE NEEDS A GRD BUSS INSTALLED ISOLATE NEUTRALS/GRDS IF NO GRD ELECTRODE TO BE INSTALLED WILL NEED A 4 WIRE FEEDER. 4. STRAP ALL POSTS TO CORBELS BEAMS. 5. FRAMING FOR HOBBY OKAY. 6. NEED MECH INSPECTION, POWER SOURCE FOR H/P AND DUCTING OR VAPOR LINES TO H/P UNIT INSIDE CHECK WITH PERSON DOING WORK.
12/31/1998 FRAMING Partial Approval OK TO INSULATE