Case: T22DV03744

Parcel: 10512017A


Addresses:

267 W LIMBERLOST DR

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
06/30/2022 INSP - INITIAL CODE ENFORCMENT Approved EVAPORATIVE COOLER IS NON-OPERATIONAL; WATER PUMP IS NOT CIRCULATING WATER AS IT IS DESIGNED. THE EVAPORATIVE COOLER IS MISSING THE FUSED EVAPORATIVE COOLER DISCONNECT. CURRENTLY ITS HARD WIRED WITH A RECEPTACLE BOX WITH UNUSED OPENINGS NOT BEING PROTECTED FROM THE WEATHER. REAR ROOM WITH HAS NO PERMANENT COOLING. WINDOW MOUNT A.C. UNITS ARE BEING USED IN PLACE OF THE INOPERABLE COOLING SYSTEM IN A NON-CODE COMPLAINT MANNER WITH EXTENSION CORDS BEING USED IN LIEU OF PERMANENT WIRING.
DOWNSTREAM ELECTRICAL PANEL HAS CONDUCTORS ENTERING THE DEVICE WITHOUT PROPER WEATHER TIGHT ACCESSORIES. INTERIOR WALL ELECTRICAL RECEPTACLES ARE LOOSE, NOT PROPERLY GROUNDED, NOT PROTECTED IN WET APPLICATIONS AREA.
STOVE RECEPTACLE SHOWS OPEN GROUND, LIVING ROOM NORTH OUTLET SHOWS OPEN GROUND. THREE PRONG OUTLET NEAR THE KITCHEN SINK IS NOT PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER. WASHER MACHINE RECEPTACLE IS NOT ANCHORED AND IS LOOSE.
REAR HOSE BIB SUPPLY LINE IS CORRODED AND LEAKING. THIS LEAK IS POTENTIALLY PENETRATING THE INTERIOR WALL CELL.