Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM08057

Parcel: 116205970


Addresses:

912 W CUSHING ST


Inspection Status: Partial Pass

Inspection History: COT - RSBU - Masonry Pregrout 

Permit Number - T22CM08057

Inspection Description - COT - RSBU - Masonry Pregrout 

Inspection Status - Partial Pass

Date Description Inspector Results Comments
05/17/2023 COT - RSBU - Masonry Pregrout  Partial Pass Partial pass on south and west wall. Rebar per plans. 1st lift okay to grout at 4'. 5/17/2023
05/23/2023 COT - RSBU - Masonry Pregrout  Partial Pass Partial pass. 1st lift all around. Okay to grout at 4'. 5/23/2023
05/25/2023 COT - RSBU - Masonry Pregrout  Partial Pass Partial pass. 2nd lift all around. Okay to grout at 8'. 5/25/2023
06/05/2023 COT - RSBU - Masonry Pregrout  Partial Pass Partial pass. 3rd lift all around. Okay to grout at 12'. 6/5/2023
06/12/2023 COT - RSBU - Masonry Pregrout  Partial Pass Partial pass 4th lift all around. Okay to grout at 16' 6/12/2023
06/16/2023 COT - RSBU - Masonry Pregrout  Passed Approved. Final lift. Okay to grout top out. 6/16/2023