Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T22CM07932

Parcel: 14036017C


Addresses:

5115 E VALENCIA RD


Inspection Status: Passed

Inspection History: COT - HCBU - Building Progress

Permit Number - T22CM07932

Inspection Description - COT - HCBU - Building Progress

Inspection Status - Passed

Date Description Inspector Results Comments
06/24/2024 COT - HCBU - Building Progress Passed
09/26/2023 COT - HCBU - Building Progress Partial Pass 9/26/25: stem wall footings on Valencia crossing per plan ok to pour. Detail C500
10/10/2023 COT - HCBU - Building Progress Partial Pass 10/10/23 Ok to continue
10/25/2023 COT - HCBU - Building Progress Partial Pass 10-25-23: Front and side entry towers are being grouted. Special 3rd party inspector is performing grout testing and approval of rebar reinforcement.
11/30/2023 COT - HCBU - Building Progress Partial Pass