Permit: T22CM07288

Parcel: 126162330


Addresses:

3931 E WHITTIER ST

Inspection Status: Canceled

Inspection History: RSEL - Electrical Progress

Date Description Inspector Results Comments
10/24/2025 RSEL - Electrical Progress Canceled
RSEL - Electrical Progress Re-inspection required 10-28-25: wrap all copper lines with R3 insulation, exterior receptacles must be weather resistant, seal exterior wall where pressure relief valve exits wall prevent infestation, seal all holes in water heater closet and correct tear in awg wire, paint all exterior plastics on rooftop, replace kitchen & dining breakers to arch fault & update breaker labeling to include living room, add shackle to water heater breaker, missing vacuum breaker on hose bib, missing hammer arrestor on dishwasher line, seal water closet.
11/05/2025 RSEL - Electrical Progress Passed 11/5/25
All corrections made.