Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Passed
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
| Date |
Description |
Inspector |
Results |
Comments |
| 10/14/2022 |
COT - RSBU - Excavation/Rebar/Zoning |
ESTEVENS |
Approved |
Entered by NGARCIA3 - Approved |
| 10/13/2022 |
COT - RSBU - Excavation/Rebar/Zoning |
TLUNDBERG |
Denied |
Entered by NGARCIA3 - DE
1. Support the ufer in the trench and isolate the vertical by 2” from any other metal
2. Remove all construction debris from pad |
| 10/12/2022 |
COT - RSBU - Excavation/Rebar/Zoning |
SCARRAZCO |
Not ready for Inspection |
Entered by VVERA1 - Not ready provide 3” of clearance all around rebar footing |
| 10/11/2022 |
COT - RSBU - Excavation/Rebar/Zoning |
TLUNDBERG |
Denied |
Entered by NGARCIA3 - DE
Maintain min 3" from rebar to earth on all sides. Maintain min 2" from holddowns and rebar to forms.
Cancel all other inspections. |