Inspection History Details
Inspection Status: Not Ready
Inspection History: RSME - Mechanical Progress
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/27/2022 | RSME - Mechanical Progress | Not Ready | ||
| 03/07/2023 | RSME - Mechanical Progress | Not Ready | 1. Provide sealed truss calcs, 2. Block register boxes, 3. Support vents mid-story & fill thru the roof, 4. Seal holes in top plate, 5. Complete lath around openings and seal penetrations, 6. New AC in garage and all new duct is not shown in the approved plans, nor is a detail for enclosing the unit hanging into the garage | |
| 05/02/2023 | RSME - Mechanical Progress | Not Ready | 1. Provide sealed truss calcs, 2. Block register boxes, 3. Support vents mid-story & fill thru the roof, 4. Seal holes in top plate, 5. Complete lath around openings and seal penetrations, 6. New AC in garage and all new duct is not shown in the approved plans, nor is a detail for enclosing the unit hanging into the garage 5/2/23: support vents mid-story and water test thru the roof, seal all penetrations n the top plate, install AC unit in garage to allow for service and to seal off from attic. |
|
| 10/04/2023 | RSME - Mechanical Progress | Passed |