Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Sewer
| Date |
Description |
Inspector |
Results |
Comments |
| 08/07/2025 |
COT - RSPL - Sewer |
|
Re-inspection required |
Underground plumbing needs to be exposed and on test prior to inspection. Missing grey water loop per plan. Plumbing lines running outside of slab require tracer wires. Blue for domestic and green for sewer. Expose all lines prior to inspection. 8/7/2025 |
| 08/13/2025 |
COT - RSPL - Sewer |
|
Re-inspection required |
8-13-25: underground plumbing cannot run in the footer. Re-route greywater/ DWV and reschedule an inspection. |
| 09/11/2025 |
COT - RSPL - Sewer |
|
Passed |
9-11-25: underground plumbing & sewer connection verified per plans-okay to backfill with shading materials. |