Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - LCEL - Electrical Final
Permit Number - T22CM01451
Inspection Description - COT - LCEL - Electrical Final
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2022 | COT - LCEL - Electrical Final | Not Ready | ||
04/05/2024 | COT - LCEL - Electrical Final | Re-inspection required | 4/5/24: all of building 3 is missing (insulation at water heaters, air gap required at condensate drain in laundry room, dishwashers not installed, T-tops missing on roof for dryer vent, UV coat plastic piping at roof, window locks), ADA unit missing (circuit at kitchen, panel schedule, bathroom and kitchen guards under sink), Unit 3208 missing lock out breaker for water heater, Unit 3207 bank plate missing at panel, Unit 3205 no power at kitchen circuit, Unit 3103 Condensate drain for A/C unit not ran, Unit 3104 water heater is not wired, Unit 3202 GFCI at kitchen not functioning properly, Unit 3301 Kitchen receptacle hot and neutral reversed and condensate not complete. Missing vent grills at breezeways. | |
04/11/2024 | COT - LCEL - Electrical Final | Re-inspection required | 4/5/24: all of building 3 is missing (insulation at water heaters, air gap required at condensate drain in laundry room, dishwashers not installed, T-tops missing on roof for dryer vent, UV coat plastic piping at roof, window locks), ADA unit missing (circuit at kitchen, panel schedule, bathroom and kitchen guards under sink), Unit 3208 missing lock out breaker for water heater, Unit 3207 bank plate missing at panel, Unit 3205 no power at kitchen circuit, Unit 3103 Condensate drain for A/C unit not ran, Unit 3104 water heater is not wired, Unit 3202 GFCI at kitchen not functioning properly, Unit 3301 Kitchen receptacle hot and neutral reversed and condensate not complete. Missing vent grills at breezeways. 4/11/24: ADA unit electrical problems with kitchen circuits. |
|
04/12/2024 | COT - LCEL - Electrical Final | Passed |