Permit: T21OT00145

Parcel: 11504475B


Addresses:

1055 N PARK AV


Inspection Status: Passed

Inspection History: COT - ENGR - Signage Final

Permit Number - T21OT00145

Inspection Description - COT - ENGR - Signage Final

Inspection Status - Passed

Date Description Inspector Results Comments
06/08/2021 COT - ENGR - Signage Final Passed {Activity date: 06/08/2021; Status: Approved; Inspector: hthrall1; Comment: Entered by HTHRALL1 - Revised plans submitted and approved 6/8/21 for MGUOD compliance.

Checking on approval of engineered plans set for mounts.} ; {Activity date: 06/01/2021; Status: Approved; Inspector: hthrall1; Comment: Entered by HTHRALL1 - Main Gate Review completed by Design Professional Rick Gonzalez on 5/30/21 and received 6/1/21. Approved, with condition to enclose the bulb channel letter sign with acrylic cover.} ; {Activity date: 05/21/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: sign review
For: wall signs /parking sign
AT: 1055 N Park Av / HUB IV
Zone: UC-1
sign permit: T21OT00145
Reviewer: H. Thrall
Date: 5/21/21

Revised plans submitted 5/11.

Referred to Main Gate review for signs exceeding 50 square feet in area overall at site and or individually. (Emailed Maria Gayosso for detail on application / fees.)} ; {Activity date: 05/03/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: sign review
For: wall signs
AT: 1055 N Park Av / SW corner of Park & Speedway (HUB IV)
Zone: UC-1 (Main Gate Urban Overlay District - MGUOD)
Sign District: Pedestrian
Reviewer: H. Thrall
Sign permit: T21OT00145
Date: 5/3/21 (2nd review)

Codes: Unified Development Code Sign Standards (UDC 7A), National Electrical Code (NEC 600), Tucson Pima County Outdoor Lighting Code (OLC), International Building Code (IBC 2018)

1. This development is within the Main Gate Urban Overlay District, thus the "UC-1 zoning requires that the signage be reviewed by the MGUOD design review process due to the sign area exceeding 50 square feet (individual and or cumulative for the site). Staff will make a referral to the MGUOD review when the following comments have been addressed:
2. Please note - plans mention " channel lettering" formations without depth noted for channel letters, and whether clear or colored acrylic covers - for each sign -are provided to meet outdoor lighting code - provide details to that effect.
A) clear covers are only allowed over 4400k max light sources, if the actual lamp is not visible to the eye. The bulb lighting on the sign are presented to show the actual filament. Provide either an opaque bulb or an opaque or translucent cover where that filament is not seen.
B) check the plans - one enlargement does show a clear cover, yet other parts of the plan do not show a cover over the bulb lit sign.

3. It is unclear whether the logo sign is a cabinet with a clear face or some channel formations with LED "faux neon" noted as open face - which will not meet outdoor lighting code - or has acrylic covers or is halo, etc, sleeves or similar? It may be helpful to provide a manufactured sample photo of similar for the review process. Provide clarity on the plan set for such - even if engineering is not yet available.

4. OLC: (see above note 2 again and 3 again - all ties into this comment as well)
A. Provide clarity on all signs that at minimum, a clear acrylic cover will be provided on all channel lettering to meet the outdoor lighting code maximum color temperature allowance of 4400k for internally illuminated signs. If these signs are not covered, they are not internally illuminated - and thus, are reviewed under different criteria and may not meet OLC standards for lumenaires per foot, lumens for the site, exceed 3500k - etc.
B. For an internally illuminated sign, no part of the actual light / lumen can be visible. For sign B - which has "bulb" style, please indicate the type of bulb (noted G25) using a photo to show it's level of opacity when lit. Depending on opacity, either a clear or translucent cover over the sign letters would apply to meet internal illumination standards.
5. Sign C - appears directly above a vehicular use area, must be 15' clearance below the sign. Check / clarify location and clearance. (Let's discuss - are there clearance bars for entry to a parking garage here? We're not connecting on this use area - appears to be vehicle entry point.)

6. Additional review comments will be provided once additional electrical and mounting details are provided. Note that special inspections for mounting will be required for the signage on the north elevation. Please give this form to Jere Murdoch, your chosen engineer, to fill out and return with the names of the qualified special inspectors and types of inspections to be performed. https://www.tucsonaz.gov/files/pdsd/forms/Special_inspection_certificate.pdf

Return corrections to Heather.Thrall@tucsonaz.gov (feel free to contact reviewer with any questions)
} ; {Activity date: 04/13/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - Revision received 4/12/21 - under review} ; {Activity date: 03/05/2021; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: sign review
For: wall signs
AT: 1055 N Park Av / SW corner of Park & Speedway (HUB IV)
Zone: UC-1 (Main Gate Urban Overlay District - MGUOD)
Sign District: Pedestrian
Reviewer: H. Thrall
Date: 3/4/21

Codes: Unified Development Code Sign Standards (UDC 7A), National Electrical Code (NEC 600), Tucson Pima County Outdoor Lighting Code (OLC), International Building Code (IBC 2018)

1. Note - the entire development consists of the parcels from Tyndall to Park, along Speedway. For sign purposes, the entire development is to be treated as Pedestrian District. This development is a mixed use within the Pedestrian District of the Sign Standards, and thus the sign area permitted is the 3 to 1 ratio of sign area per street development frontage.
2. This development is within the Main Gate Urban Overlay District, thus the "UC-1 zoning requires that the signage be reviewed by the MGUOD design review process due to the sign area exceeding 50 square feet (individual and or cumulative for the site). Staff will make a referral to the MGUOD review when the following comments have been addressed.
3. Enlarge all font on the plans to a minimum of 12 point for legibility.
4. IBC - no attachment details were provided for this review. The sheets provided mention an "engineering" package. Please provide for the review to be conducted. If not yet available, please address these comments below with standard diagrams.
5. Clarify what sign B is mounted to…? Enlarge, call out the surface - is this a canopy sign or mounted flat against a component of the building?
6. Please note - plans mention " channel lettering" formations without depth noted for channel letters, and whether clear or colored acrylic covers - for each sign -are provided to meet outdoor lighting code - provide details to that effect.
7. It is unclear whether the logo sign is a cabinet with a clear face or some channel formations with LED "faux neon" noted as open face - which will not meet outdoor lighting code - or has acrylic covers or is halo, etc, sleeves or similar? It may be helpful to provide a manufactured sample photo of similar for the review process. Provide clarity on the plan set for such - even if engineering is not yet available.

8. NEC. 600
A. Provide volts, amps and circuit data for each sign.
B. Provide side view of each sign and identify the shut off switch
C. Provide notations where circuits will be for the signs and provide lock outs at panel.

9. OLC:
A. Provide clarity on timer note that the signs will shut off at midnight curfew.
B. Provide clarity on all signs that at minimum, a clear acrylic cover will be provided on all channel lettering to meet the outdoor lighting c
06/16/2021 COT - ENGR - Signage Final hthrall Continued Entered by HTHRALL1 - SPECIAL INSPECTIONS REQUIRED FOR MOUNTING - DO NOT FINAL UNTIL CERTS RETURNED COMPLETED / SEALED BY ENGINEER