Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/18/2021 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL OUT BY TFD: EMERGENCY CALL OUT BY TFD: THE INVESTIGATOR DISCOVER 4 IGNITIONS SOURCES INSIDE THE BUILDING. THERE IS FIRE DAMAGE TO THE FOLLOWING LOCATIONS: DINING, LIVING AND BATH ROOM. THERE ARE 4 TRUSSES BETWEEN THE LIVING ROOM AND DINING ROOM WHICH HAVE SEVERE DAMAGE TO ENDS WHERE THEY CONNECT TO THE LOAD BEARING WALL THIS LOAD BEARING WALL SEPARATES THE MAIN HOME AND THE ATTACHED ADDITION. THIS WALL HAS SEVERE DAMAGE TO 4 RAFTERS AND MULTIPLE WALL STUDS. THERE ARE MULTIPLE ROOF CUT OUTS. THERE IS MAJOR DRYWALL DAMAGED IN ALL ROOMS BOTH WALL AND CEILING. THE GARAGE ALSO HAS CEILING DAMAGE. DAMAGE TO THE CEILING DRYWALL. THE BEDROOM WINDOW IS DAMAGED ALONG WITH OTHER ROOMS. THERE IS A IN GROUND IN THE BACK YARD, THE IRON GATE DOES NOT HAVE SELF LATCHING LOCK MECHANISM. THE GATE CAN NOT BE LOCK. THE GATE WAS PINNED SHUT. ELECTRICAL: THE ABOVE DAMAGED AREAS HAVE BARE AND BURNT WIRING ALONG WITH MELTED DEVICES / OUTLETS. TEP DID DISCONNECT POWER. PLUMBING: SWG DID PIN METER OFF MECHANICAL: HEAVY SMOKE REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY. THE UNFIT TO OCCUPY PLACARD WAS POSTED ON THE GARAGE DOOR. NOTICE AND ORDER WAS POSTED ON THE FRONT DOOR. THE DAMAGED OPENING WAS BOARDED BY THE CITY OF TUCSON |