Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE
Address:

Entered Date:

06/18/2021

Applicant:

HOLLY K GARCIA

Description:

TFD CALL - RESIDENTIAL HOUSE FIRE EVENT # F211690098

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV03834
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/18/2021 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: EMERGENCY CALL OUT BY TFD: THE INVESTIGATOR DISCOVER 4 IGNITIONS SOURCES INSIDE THE BUILDING. THERE IS FIRE DAMAGE TO THE FOLLOWING LOCATIONS: DINING, LIVING AND BATH ROOM. THERE ARE 4 TRUSSES BETWEEN THE LIVING ROOM AND DINING ROOM WHICH HAVE SEVERE DAMAGE TO ENDS WHERE THEY CONNECT TO THE LOAD BEARING WALL THIS LOAD BEARING WALL SEPARATES THE MAIN HOME AND THE ATTACHED ADDITION. THIS WALL HAS SEVERE DAMAGE TO 4 RAFTERS AND MULTIPLE WALL STUDS. THERE ARE MULTIPLE ROOF CUT OUTS. THERE IS MAJOR DRYWALL DAMAGED IN ALL ROOMS BOTH WALL AND CEILING. THE GARAGE ALSO HAS CEILING DAMAGE. DAMAGE TO THE CEILING DRYWALL. THE BEDROOM WINDOW IS DAMAGED ALONG WITH OTHER ROOMS. THERE IS A IN GROUND IN THE BACK YARD, THE IRON GATE DOES NOT HAVE SELF LATCHING LOCK MECHANISM. THE GATE CAN NOT BE LOCK. THE GATE WAS PINNED SHUT. ELECTRICAL: THE ABOVE DAMAGED AREAS HAVE BARE AND BURNT WIRING ALONG WITH MELTED DEVICES / OUTLETS. TEP DID DISCONNECT POWER. PLUMBING: SWG DID PIN METER OFF MECHANICAL: HEAVY SMOKE REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY. THE UNFIT TO OCCUPY PLACARD WAS POSTED ON THE GARAGE DOOR. NOTICE AND ORDER WAS POSTED ON THE FRONT DOOR. THE DAMAGED OPENING WAS BOARDED BY THE CITY OF TUCSON
07/07/2021 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCS SCANNED INTO ONBASE. CLOSE CASE

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T21DV03834
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
06/18/2021 CONTACTED IN PERSON
06/18/2021 NOTICE AND ORDER ISSUED
06/18/2021 VIOLATION CLOSED
12/07/2021 SEC LEIN PLACED ON PROPERTY IN THE AMOUNT OF ???
06/18/2021 STRUCTURE SECURED BY ???
06/18/2021 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
431 NOV.PDF DOCUMENTS VIEW
20210618_092913.JPG DOCUMENTS VIEW
20210618_092934.JPG DOCUMENTS VIEW
20210618_093017.JPG DOCUMENTS VIEW
20210618_093022.JPG DOCUMENTS VIEW
20210618_093044.JPG DOCUMENTS VIEW
20210618_093211.JPG DOCUMENTS VIEW
20210618_093235.JPG DOCUMENTS VIEW
20210618_093344.JPG DOCUMENTS VIEW
20210618_124612.JPG DOCUMENTS VIEW
20210618_124835.JPG DOCUMENTS VIEW
20210618_124903.JPG DOCUMENTS VIEW
20210618_124911.JPG DOCUMENTS VIEW
20210618_125031.JPG DOCUMENTS VIEW
20210618_130714.JPG DOCUMENTS VIEW
20210618_130718.JPG DOCUMENTS VIEW
20210618_133820.JPG DOCUMENTS VIEW