Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T21DV01816
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/04/2021 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE, MET WITH TFD INVESTIGATOR AND FACILITIES MANAGER FOR SALPOINTE HIGH SCHOOL. THE DESCRIPTION FROM TFD WAS THAT A LIGHT IN THE COCHRON THEATRE HAD SHORTED OUT, PORTIONS OF THE LIGHT MELTED AND DROPPED TO THE SEATING NEAR THE STAGE OF THE THEATRE. A FIRE SPRINKLER NEXT TO THE LIGHT ACTIVATED, A SECTION OF THE SEATING ALSO CAUGHT FIRE BUT WAS EASILY PUT OUT. TFD AND FACILITIES MANAGER ISOLATED THE ELECTRICAL TO THE LIGHTS. TFD TURNED THE WATER OFF AT THE RISER ROOM ALSO LOCATED IN THE THEATRE. MANAGER INFORMED US THAT THE REMODEL OF THE THEATRE WAS JUST COMPLETED A COUPLE OF MONTHS AGO, SO HE CONTACTED DIVERSIFIED CONSTRUCTION. WHO BEFORE COMING OUT CONTACTED TRIPLE A FIRE FOR THE SPRINKLER SYSTEM, CONTACTED OLD PUEBLO THEATRE LIGHTING FOR THE DAMAGED LIGHT. FACILITIES CONTACTED T&M RESTORATION FOR THE WATER EXTRACTION AND CLEAN UP AND LEFT A MESSAGE FOR SEATING, A COMPANY OUT OF PHOENIX AND SPECIAL ORDER. NOV WAS ISSUED TO SALPOINTE HGIH SCHOOL FOR PERMITS REQUIRED, AND SUGGETED THEY REOPEN AND USE THE SAME PERMIT NUMBER FOR THE REMODEL. BEFORE LEAVING DIVERSIFIED ARRIVED ON SITE. STATED TRIPLE A WAS IN ROUTE TO CHANGE THE SPRINKLER HEAD AND RESTORE WATER TO THE RISER, AND T&M WAS ALSO IN ROUTE. I LATER RECEIVED A CALL FROM FACILITIES STATING THAT THE SEATING AREA HAD BEEN CLEANED, WATER EXTRACTED AND SEVERAL SEATS REMOVED, FANS ADDED TO THE CARPET AND HELP REMOVE THE FIRE SMELL. TRIPLE A HAD ALSO ARRIVED, REPLACED THE SPRINKLER HEAD AND RESTORED WATER, THEY ALSO CONTACTED TFD TO REINSPECT. THE ELECTRICAL LIGHTING WAS ISOLATED AN SEVERAL BREAKERS WERE TURNED BACK ON TO THE THEATRE WITH THE HELP OF DIVERSIFIED CONSTRUCTION. C/E HAS NO FURTHER ISSUES AS THE LIGHT REPAIR, AND SEATING REPLACEMENT IS ALL THAT IS LEFT TO REPLACE BEFORE ELECTRICAL CAN BE RESTORED. COMPLAINCE / CLOSE CASE. |