Permit: T21CM07236

Parcel: 117091080


Addresses:

1121 S 11TH AV

Inspection Status: Not Ready

Inspection History: COT - LCPL - Plumbing Intermediate 

Date Description Inspector Results Comments
10/27/2022 COT - LCPL - Plumbing Intermediate  Not Ready
09/18/2026 COT - LCPL - Plumbing Intermediate  Not Ready
10/09/2026 COT - LCPL - Plumbing Intermediate  Re-inspection required Here are the notes from today.

10/9/26: Dryers duct cannot be double wall pipe per IMC and manufacturer requirements. Dryers cannot share dryer Duct ( 1st and 2nd floor unit) cannot tie into (3rd and 4th unit). Exhaust fans must be UL listed and shall have appropriate sized duct. Revision required for mechanical modifications. 5-sided gypsum box required at refrigerator boxes .