Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T21CM07236

Parcel: 117091080


Addresses:

1121 S 11TH AV

Inspection Status: Not Ready

Inspection History: COT - LCME - Mechanical Progress 

Date Description Inspector Results Comments
10/26/2022 COT - LCME - Mechanical Progress  Not Ready
09/01/2026 COT - LCME - Mechanical Progress  Partial Pass 9-1-26: MEP progress inspection on unit's 10-firecaulk feeder penetrations at decking & above ceiling, strap mini split feeders, insulate hot pet lines 3/4" and larger, add plastic bushings at sub panels, block block party walls at wall gaps, 8-same notes, cou-le of units on 2nd floor-ground pancake box, putty pack required at party walls when receptacles are within 2' from each other, strap/secure exhausts within 2' of a bend and at 4' intervals thereafter, plastic bushings at panel and insulation of hot pex lines, seal penetrations at top plates, decking and at party walls.