Date Description Inspector Results Comments
10/26/2022 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready
03/17/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Unit 1. Not ready. Provide DWV test. Staple has punctured ABS line in hall bathroom. Space pex line from any can lights minimum 12”. Exhaust duct needs to be connected in master bedroom. Finish make in receptacles. Add staple to electrical line in kitchen. 3/17/2023
03/23/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 3/23/2023 approved. Corrections were made.