Inspection Status: Passed
Inspection History: COT - RSEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 02/24/2026 |
COT - RSEL - Electrical Final |
|
Passed |
NOTE: Unable to move toilet to meet ADA standards as a structural beam is located beneath area in question: cannot cut beam to allow the toilet to be moved. The location of the toilet will be accepted as correct for this structure. |
| 12/02/2025 |
COT - RSEL - Electrical Final |
|
Re-inspection required |
12/2/25: Arc-fault required at smoke detectors and laundry room, patch work required at exterior throughout, properly terminate condensate drain with 90 degree fitting, lights not working throughout, roof drain is missing guard at 3rd floor, stair lighting not functioning, water closet requires 15" clearance on both sides, GFCI required in laundry rooms, seal penetrations around duct in mechanical room, lock out required at water heater, secure electrical whip at air handler, leak at refrigerator area from next door unit must be opened and addressed, no power at exterior receptacles, appliances must be installed, kitchen exhaust must be installed, |