Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSME - Mechanical Final
Permit Number - T21CM04992
Inspection Description - COT - RSME - Mechanical Final
Inspection Status - Canceled
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/04/2022 | COT - RSME - Mechanical Final | Canceled | Inspection Canceled | |
| 12/02/2025 | COT - RSME - Mechanical Final | Re-inspection required | 12/2/25: Arc-fault required at smoke detectors and laundry room, patch work required at exterior throughout, properly terminate condensate drain with 90 degree fitting, lights not working throughout, roof drain is missing guard at 3rd floor, stair lighting not functioning, water closet requires 15" clearance on both sides, GFCI required in laundry rooms, seal penetrations around duct in mechanical room, lock out required at water heater, secure electrical whip at air handler, leak at refrigerator area from next door unit must be opened and addressed, no power at exterior receptacles, appliances must be installed, kitchen exhaust must be installed, |