Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - HCBU - Interior Shear Bracing
Permit Number - T20CM02722
Inspection Description - COT - HCBU - Interior Shear Bracing
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/26/2022 | COT - HCBU - Interior Shear Bracing | Not Ready | ||
10/12/2022 | COT - HCBU - Interior Shear Bracing | TGAUSP | Partial Approval | Entered by VVERA1 - Partial for fire rate walls at 1st floor mail room, 2nd, 3rd and 4th floor electrical rooms. |
10/04/2022 | COT - HCBU - Interior Shear Bracing | JBURGE | Partial Approval | Entered by RSALDAT1 - Partial. Mechanical room C116; North stairwell ceiling at level #4. Ok to tape progress areas. |
09/29/2022 | COT - HCBU - Interior Shear Bracing | WGALLAGHER | Partial Approval | Entered by NGARCIA3 - Partial approval for north stair well first layer on all floors on shear wall in adjoining guest rooms and for second layer in duct shafts And south stair on 4th floor only first layer in corridor |
09/28/2022 | COT - HCBU - Interior Shear Bracing | JBURGE | Not ready for Inspection | Entered by VVERA1 - . Not ready. Contractor cancelled. |
09/27/2022 | COT - HCBU - Interior Shear Bracing | JBURGE | Partial Approval | Entered by NGARCIA3 - Partial. Two each air shafts on Levels #1 through level #4. Ok to tape layer one and apply layer #2 of sheet rock. Condensate shafts on Level #1 and #2. Ok to sheet rock progress areas. |
09/22/2022 | COT - HCBU - Interior Shear Bracing | WGALLAGHER | Partial Approval | Entered by NGARCIA3 - Partial approval for north duct shaft 1" layer ok to cover and nailing on south duct shaft ok to tape north and east 1st layer of X drywall Partial approval for guest room B402 ok to drywall interior adjoining stair well |
09/21/2022 | COT - HCBU - Interior Shear Bracing | WGALLAGHER | Partial Approval | Entered by VVERA1 - Partial approval stair 2nd layer on west wall and soffits in 4th floor guest rooms |
09/20/2022 | COT - HCBU - Interior Shear Bracing | WGALLAGHER | Partial Approval | Entered by NGARCIA3 - Sheetrock nailing for the south duct chase 1st 1" layer floor 1-4 |
09/13/2022 | COT - HCBU - Interior Shear Bracing | WGALLAGHER | Partial Approval | Entered by NGARCIA3 - Partial approval for above ceiling in corridor 4th floor only and soffits ok to tape |
09/02/2022 | COT - HCBU - Interior Shear Bracing | JBURGE | Partial Approval | Entered by VVERA1 - Partial. Level #4 corridor ceilings; RC Channel. Ok to cover progress areas. |
08/04/2022 | COT - HCBU - Interior Shear Bracing | DMUNIZ | Partial Approval | Entered by NGARCIA3 - Partial, first layer of north elevator shaft fire barrier ok for 1st and 2nd floor |
02/03/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | partial approval for first floor RC in A wing corridor, and 2nd floor B wing drywall nail corridor and guest rooms | |
02/28/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | partial approval for west stairway screw nailing | |
03/01/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | 3/1/23 first floor guest rooms drywall nailing ok to tape | |
03/03/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | for north stair well soffit area at elevator and stair well and first layer on south elevator | |
03/08/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | Mechanical and electrical closets okay to add second layer of gypsum board. | |
03/09/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | partial approval for first floor south elevator 2nd layer drywall | |
03/14/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | ||
03/19/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | RC in back of house ok for drywall | |
03/28/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | 1st floor corridor to lobby A WING ok to tape | |
03/28/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | ok to tape corridor A wing including lobby 1st floor | |
04/04/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | partial approval for back of house first floor ok to tape | |
04/05/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | ||
04/05/2023 | COT - HCBU - Interior Shear Bracing | Partial Pass | ||
04/07/2023 | COT - HCBU - Interior Shear Bracing | Passed | ||
10/31/2022 | COT - HCBU - Interior Shear Bracing | Partial Pass |